USE:
Roentgenoscopy; Digestive track spot film photograpy; General photograpy; Filter-ray device photograpy
MAIN TECHNICAL PARAMETER:
1. Single bed and single tube
2. Rotary anode X-ray tube unit and tangential pipe sleeve.
3. monophase full-wave rectification high-voltage generator.
4. Supply voltage V, roentgenoscopy and photograpy kV, infinitely variable control and electric mechanism.
5. Equipped with capacity protective circuit,and kV mAs sectional and graduated interlock protection.
6. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly.
8. Equipped with the digital circuit device for roentgenoscopy time accumulation.
9. Examining bed is of electric back rotation, with external balance structure and with vibrating filter-ray device.
10. The spot film device of luminescent screen can hold the film jacket of various sizes and solenoid valve locking.
11. Upright post is of top and bottom track. It moves lightly.
|
ITEM
|
CONTENT
|
INDEX
|
|
Fluoroscopy
|
voltage
|
40~100kV be adjustable continuously
|
|
current
|
0.5~5mA
|
|
Photograpy
|
voltage
|
40~100kVbe adjustable continuously 40~125kV be adjustable
|
|
current
|
small focus 50mA and big focus 30 、 100 、 150 、 200mA,five grades
|
|
spot film
|
150mA( fixed )
|
|
time
|
0.04~6.3s 23 grades together
|
|
High-voltage generator
|
capacity
|
20kVA( instantaneous )
|
|
Max dc output voltage
|
100KV 125KV ※
|
|
Max dc output current
|
200mA
|
|
X_ray tube
|
model
|
XD51-20.40/100 XD51-20.40/125 ※
|
|
focus
|
1×1mm 2×2mm
|
|
Examining bed
|
rotary angle
|
+90°~ 0 ° ~ -10°
|
|
movable range of spot film device(stomach and intestines photograpy)
|
lengthwise 580mm
|
|
transverse ± 90mm
|
|
pressure down 300mm
|
|
specification of spot film
|
127×177.8mm(5”×7”)
|
|
203.2×254mm(8”×10”)
|
|
254×304.8mm(10”×12”)
|
|
279.4×355.6mm(11”×14”)
|
|
filter-ray
|
grid characteristic
|
N28
|
|
converging distance
|
fo 100cm
|
|
grid proportion
|
r8
|
|
distance between bed face and film
|
70mm
|
|
collimator
|
manual single blade
|
|
Upright
|
adjusting scope(distance between top and bottom track)
|
2800-3400mm
|
|
move lengtwise (along top and bottom track)
|
3100mm
|
|
move transverse(along horizontal arm )
|
800mm( from bulb focus to he centre of upright post)
|
|
move up and down (along upright post)
|
325~1830mm( from bulb focus to groud)
|
|
Power supply
|
Voltage
|
380V/220V
|
|
Frequency
|
50Hz ± 0.5Hz
|
|
Inner resistance
|
380V:0.9 Ω ,220V:0.3 Ω
|
UNIT CONFIGURATION
Control desk high-voltage generator unit high voltage cable X-ray tube assembly
Radiographic table-pillar of X-ray source collimator