USE:
·Fluorscopy
·Gastrointestinall radiography
·General radiography
·Ray-filter-ray radiography
MAIN CHARACTERISTICS:
|
·Two tables and two tubes X-ray machine is separate and special, with fluoroscopy, gastrointestinal photography, general photography, filter-ray photography.
·Three parameters kV mA and s are sectional interlocked protection in capacity.
·Both fluoroscopy and photography are equipment with limited time protection fittings.
·Equipment with protection of the manostat for filament of X-ray tube, Space charge compensating, Rotary anode starting and overrunning–temperature protection.
·Supply power V, fluoroscopy kV, photography kV and motor adjusts continuously.
·Equipment with the electric diagnostic bed, fluorescent photography device and electromagnetism locks
·The photography table can be used professionally, operated expediently, the ground-track is selected fittings when using .
|
QUALITY PARAMETERS:
|
ITEM
|
CONTENT
|
INDEX
|
|
Outer power
|
Capacity
|
25KVA
|
|
Ultuge freguency
|
380V/220V±10% 50Hz±1Hz
|
|
Inner resistanle
|
at 380V:0.9Ω; at 220V:0.3Ω
|
|
Supply control
|
Scope
|
380V±10% being adjustable or 220V±10% being adjustable
|
|
High-volage generator
|
Max-capacity
|
20kVA(instantaneous)
|
|
Max Dc output voltage
|
125kVP
|
|
Max Dc output cunent
|
200mA(instantaneous)
|
|
Fluorscopy
|
Tube voltage
|
50~100kV being adjustable
|
|
Tube cunent
|
0.5~5mA being adjustable
|
|
Gastrointestinall radiography
|
Tube voltage
|
50~110kVP
|
|
Tube cunent
|
150mA(fixed)
|
|
Fluorscopy Gastrointestinall radiography X-Ray tube
|
Focus
|
small focus 1×1mm; big focus 2×2mm
|
|
Model
|
XD51-20、40/125
|
|
General radiography、filter-ray radiography
|
Tube voltage
|
50~125kVP
|
|
Tube cunent
|
small focus 50、100mA; big focus 50、100、150、200mA
|
|
Raiography X-Ray tube
|
Focus
|
small focus 1×1mm, big focus 2×2mm
|
|
Model
|
XD51-20、40/125
|
|
Dnagnostic bed
|
Rotary scope
|
90°~0°~—10°
|
|
Bed L×W×H
|
1960×702×820mm
|
|
Fluorscopy Gastrointestinall radiography equipment
|
Horizontal
|
about ±90mm
|
|
Up and down
|
580mm
|
|
Lock mode
|
The electromagnetism locks
|
|
Light control
|
Manual limit beam single leaf
|
|
Photograph specification
|
128×179mm(5”×7”)Whole slice two cents slice
|
|
205×254mm(8”×10”)Whole slice two cents slice
|
|
254×305mm(10”×12”) Whole slice two cents slice
|
|
279×355mm(11”×14”) Whole slice four cents slice
|
|
Radiography bed
|
L×W×H(mm)
|
2000×710×700mm
|
|
Lengthwise
|
700mm
|
|
Transrerse
|
|
|
Vihration Ray-filter device
|
Travel in length 》550mm
|
|
Grid clennsity N28
|
|
grid ratio r8
|
|
Convergence distance f0100cm
|
|
X-Ray tube unit-support
|
Lengthwise
|
2100mm
|
|
Up and down
|
325~1825mm
|
|
Tube turning around the shaf of arm
|
180°
|
|
Turning around the shaft of tube
|
-10°~90°~120°
|
Unit Configuration
Control desk high-voltage generator unit X-ray Tube unit support I Diagnostic Bed
X-ray Tube unit support II Radiography bed Stanal radiography post